Quality

Quality first begins inside and then it works its way out. We believe in accuracy and we raise the quality standard of our products as much as we can. Our principle is that the job cannot be finished before it is improved to please the customers. We work as closely as possible to reach our boundaries of our abilities.

Our Products and associated technology serves the industries that are extremely diverse in their requirements. In particular, factors such as Castings acceptance levels vary considerably from one type of user to another. Experience has shown that it is not viable to develop a universal system to meet the varying requirements. In response to this situation, we offer open examination of our methods and systems by the user or his appointed representative. This type of examination may be considered on a single contract basis or as a regular user basis.

Testing & Inspection

(1) AS PER ASTM F-1545-97 FOR WHITE PTFE.

(2) AS PER ASTM F-781 FOR WHITE PFA.

(3) AS PER ASTM F-546 FOR WHITE FEP.

VISUAL : All Spool Pipes, Fittings & Valves are inspected visually to ensure that there is

(1) No evidence of Pinholes, Porosity or Cracks.
(2) Fitment of the liner with the Pipes & Housing is proper.
(3) The Gasket seating surface of the Lining is Free Scratches, Dents, Nicks or any tool marks.

HYDROSTATIC TEST

All pipes, fittings & Volves are subject to a 20kg/ Cm2 HYDROSTATIC PRESSURE test at room temperature using clean Water before and after lining to ensure that there is no evidence of any leakage.

ELECTRONIC TEST

All Spool Pipes, Assemblies & Fittings are subject to 15,000 V Non-Destructive HIGH VOLTAGE ELECTROSTATIC Spark Test to ensure that there is no evidence of defects like Pin Holes, Micro Porosity or cracks in the liner.

VACUUM TEST

Spool Pipes, Assemblies & Fittings are subjected to full Vaccum test at 1.0 kg/cm2 at 190 DEG. C to ensure that there should not be any Bulging or Bucking or Collapse of the liner.